TEL: 687-6451 FAX:687-6452
e-Mail : inquire@solutionsgeneral.com

 

CHARACTERISTICS OF CBRT

Test circuit breaker to trip if the       current  passing through it, is 125%       of the trip unit setting or higher.

Test if motor over load relay       protector initiates tripping if the O.L       current setting has been reached or       when its value is greater than the       setting.

Can test other protective relays like       27, 50/51, 59 etc.

When buying new breakers, relays,       etc. this CBRT can be used to check if       they really operate functionally to       trip when energized at faulted       condition.

Can drive current up to 10,000       Amperes, depending on the model       you will order. The ratings available       are 0 – 1000 Amps, 0 – 2000 Amps, 0       – 3000 Amps, 0 – 4000 Amps, 0 –       5000 Amps, 0 – 6000 Amps, and 0 –       10,000 Amps. Customized ratings       above 10.000 Amps can be       manufactured if customer so orders.

Readily available in the Philippines       delivered to your doorstep 15 days       upon receipt of 50% Down payment       and Purchase Order.

Free training and orientation for       your engineers and technicians on       its proper use, for one week.

It can measure elapsed time at 0.01       seconds resolution.

Available only at SOLGEN, INC and its       satellite dealers
FAQs
( UNDER CONSTRUCTION)

 CIRCUIT BREAKER AND RELAY TESTER (CBRT)


, Inc.

Are you the man-in-charge? Then take action and don’t be blamed for:
         
a)
Fires brought about by “ faulty electrical wiring” resulting to loss of property, loss of jobs and sometimes even loss of lives!!!
b)
 
Unwanted Burning of Electric Motor Windings (due to non-activation of motor overload protective devices or relays) that lead to:
1)
Work Stoppage. Loss of production & loses due to downtime,
2)
Wasted time and money on rewinding of motor windings & on poor quality rewinding work,
3)
Wasted man-hours in removing the burnt motor,
4)
  Wasted man-hours in installing back newly rewound motor
 
by using SOLGEN, Inc’s CIRCUIT BREAKER & RELAY TESTER (CBRT), the only TEST SET that can simulate Overload & Short Circuit scenarios and test the tripping capabilities of your Circuit Breakers & other protective devices up to 10,000 amperes. Can be used also for over current as well as over & under voltage relays.
 
For more information on this life and money-saving equipment, please contact Your Accounts Manager or call our Engineering Department.
Don’t delay… call us now !!! We hate for you to be the guy below:

which be business organizat

Partners

Copyright ©2007 Solutions General in Electrical & Electro-Mechanical Needs, Incorporated
All Rights Reserved

Design provided by Free Web Templates - your source for free website templates